Jesteśmy dostawcami wysokiej klasy analizatorów biochemicznych, posiadamy w swoich magazynach analizatory biochemiczne renomowanych firm takich jak Abbott Diagnostics czy Siemens. Są to niezawodne urządzenia umożliwiające dokładny pomiar glukozy, sacharozy, laktozy, kwasu mlekowego, galaktozy, glutaminiany i kwasu glutaminowego. Zapraszamy do kontaktu z naszym zespołem specjalistów w celu przesłania aktualnej ofert analizatorów biochemicznych.
ARCHITECT c8000 – Advanced clinical chemistry analyzer
Manufactures: Abbott Diagnostics
Method: Photometric, Potentiometric, Turbidimetric
Max. throughput: Up to 1200 tests/hour
Sample Types: Serum, Plasma, Urine, CSF
Sample Result Storage: 50 000
ARCHITECT c8000 consistent STAT turnaround time. Large load-up capacity. ARCHITECT c8000 Clinical Chemistry Analyzer provides all these benefits to help you achieve excellent first-time results.
Analizator biochemiczny Skyla HB1
Kliniczny analizator biochemiczny Skyla HB1 jest specjalistycznym, profesjonalnym systemem do przeprowadzania diagnostyki biochemicznej in-vitro dla laboratoriów medycznych i klinik. Jest niewielki, przenośny i można szybko uzyskać wyniki. Kliniczny analizator biochemiczny wykorzystuje precyzyjną fotometryczną technologię pomiarową, w połączeniu z jednorazowymi płytami odczynnikowymi. Jest to w pełni automatyczny system mogący pracować bez nadzoru. Wbudowana kontrola jakości i kalibracja każdego testu.
Pomiar w 15 minut, aż do 15 parametrów jednocześnie!
Siemens
ADVIA® 1200 Chemistry System
The Flexibility of Innovation
Compact Size
The ADVIA® 1200 system features a small footprint, which allows it to fit comfortably in any size laboratory.
Productivity – Reliability – Expertise
1. Sample Tray
Capacity for 84 patient samples. Separate access to refrigerated area for on-board calibrators and controls.
2. Sample Probe
Sampling system includes liquid level sensing, short sample detection and clot detection. The ADVIA 1200 system has minimal requirements for sample volume (as low as 1 µL/test).
3. ISE System
Indirect Na+, K+, Cl-.Compact, easy to replace, long-life electrodes guaranteed for 30,000 tests per electrode.
4. Cuvette-based Reaction Tray
Segmented tray for easy cuvette replacement. This advanced, high precision optical system combines with a unique incubation fluid and a concavity diffraction grating to ensure superior precision and accuracy in clinical chemistry instrumentation.
5. Reagent Storage Area
Refrigerated storage for 41 one- or two-reagent chemistries plus open system capability – providing total workstation consolidation.
The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins like Cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers:
Throughput of up to 1,800 tests per hour provides speed to keep pace with workload peaks
200 basic metabolic panels per hour to meet turnaround-time demands
Large onboard reagent capacity and optional concentrated reagents to reduce interruptions
Optimal standardization of reagents and systems for efficient consumable usage
Refrigerated onboard storage of controls and reagents for extended stability and increased productivity
Automation ready design – no additional hardware required
Typ: Horiba ABX Pentra 400

- Wielkość aparatu: 101 x 71 x 63 cm
- Waga aparatu: 120 kg
- Wielkość jednostki chłodzącej: 29 x 42 x 40 cm
- Waga jednostki chłodzącej: 35 kg
- Drukarka: laserowa
- Poziom hałasu: < 66dB
- Zewnętrzna temperatura pracy: od 15 oC do 32 oC
- Zewnętrzna wilgotność pracy: 20 do 80%
- Całkowita moc zasilania (z drukarką) 1000 VA
- Woda: destylowana – zbiornik 10 L
- Cechy wody: oporność >5M?, przewodnictwo < 2µS/cm
Do 420 testów na godzinę z modułem ISE
ABX Pentra 400 jest kompaktowym analizatorem biochemicznym typu „benchtop”.
Wysoka autonomia i możliwość ciągłego ładowania próbek i odczynników zapewniają dużą wydajność, łatwość obsługi oraz wysoki komfort pracy.
Innowacyjne cechy:
- 55 testów na pokładzie
- Innowacyjny format kaset
- Zintegrowany system walidacji
- Ekran dotykowy
- Podgląd aktualnie wykonywanych testów w czasie rzeczywistym
Ideal for „hot lab” working.
Integrated Workstation with Color Touch Screen.
Micro-sampling from whole blood (CBC: 35 µL – DIFF: 53 µL).
Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) – DHSS* Technology.
Perfect homogenization of blood samples with reagents – MDSS** Technology.
Features
ABX Pentra XL 80
Throughput: Up to 80 samples/hour
Large capacity auto-loader (100 tubes)
Stat sampling on open or closed tubes
Automatic Sample Re-run
Reagents: Only 4 onboard reagents and 1 diluent
Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix
Basophils counted through specific channel
High resolution matrix
Customized Dilution Ratio (CDR)
Integrated Validation Station
* DHSS: Double Hydrodynamic Sequential System (HORIBA Medical Patent)
** MDSS: Multi-Distribution Sampling System (HORIBA Medical Patent)
Wydajność 200 oznaczeń fotometrycznych na godzinę bez ISE, do 300 oznaczeń na godzinę z ISE (Na, K, Cl, Li)
Aparat typu bench top
40 pozycji odczynnikowych
40 pozycji próbkowych
Chłodzenie odczynników i próbek badanych na pokładzie analizatora
Detektor poziomu cieczy, detektor kolizji, pomiar pozostałej ilości odczynnika
Kuwety reakcyjne jednorazowego użytku
Niskie koszty oznaczenia
Minimalna objętość reakcyjna – 180 µl
Maksymalne zużycie wody do 3,5l/h
Szeroki panel badań
- Wydajność: 300 testów na godzinę
- Testy wykonywane jednocześnie: 25 (dla 2 odczynników); 750 (pojedynczy odczynnik)]
- Zakres: biochemia, immunologia, TDM
- Typy testów: metoda punktu końcowego, metoda kinetyczna. Dodatkowo stosowana jest metoda monochromatics and Bichromatics
- Próbki STAT: mogą być włożone od razu z przypisanym wysokim priorytetem
- Automatyczny ponowny rozruch
- Rotor: 80 kuwet reakcyjnych
- Autmatyczne załadowywanie/wyładowywanie kuwet
- System fotometryczny: filtry interferencyjne o zróżnicowanej długości fal; statyczne włókna optyczne
- Czas pomiaru: 12 sekund
- Wymiary: 980mmX710mmX1190mm(Długość x Szerokość x Wysokość)
- Waga: 175kg

Random Access Analyzer
– Throughput of 240 test/hour
– Clinical Chemistry ad Turbidimetry dedicated reagents
– 30 refrigerated positions by 20 and 50 mL reagents bottles
– Refrigeration system with switch independent from analyzer
– 3 positions without refrigeration for sample and reagent racks
– 24 samples per rack. Maximum capacity of 72 samples
– Maximum capacity of 52 reagents
– New dispenser arm assembly
– Low dead volume sample and reagent
– Impact detection system
– Recalibration automatic positioning of needle
– Primary tubes or pediatric cups as sample containers
– Unlimited STAT capabi1ities. Run at anytime
– Up to 15 minutes reading time
– Reaction volume between 200 and 800 uL
– Measurement Range from -0.05 A to 2.5 A
– Spectral range 340 at 900 mm
– Hard Coating Filter (340, 405, 505, 535, 560, 600, 635, 670nm)
– Automatic conditioning of system fluid
Humalyzer 2000 – Semi-Automatic Photometer with integrated incubator
Specification
Manufactures: Human
Method: Spectrophotometric
59 programmable methods
Wavelengths: 340, 405, 505, 545, 580, 630 nm
Memory: for 255 samples, calibrations
Incubator: Integrated incubator with 12 round positions
Printer: Internal thermal printer
Compact semi-automated Humalyzer 2000 is perfectly suited for small- to medium-sized laboratories and as back-up analyzer.

MODEL
Express Plus
OPEN TEST MODES 48
POWER NEEDED, VAC (ENERGY) 110
CONFIGURATION BenchtopRandom access
YIELD, 20 TEST PROFILES/HR 9
PROCESSOR INTERFACE (WATER REQUIREMENTS, L/min) Bidirectional RS232C
DRUG ASSAYS
Digoxin (DRUG ASSAY/TIME, min) See below
Additional (Alarms, high/low) Syva applications for TDM and DAUs; Microgenics
SAMPLE SIZE/RANGE µL (SAMPLE REQUIREMENTS) 3-30
AUTO DILUTION (PURCHASE INFORMATION) Yes
BASIC CHEMISTRIES
Albumin (BASIC/TIME, min) Yes
Alp (BASIC/TIME, min) Yes
Alt (BASIC/TIME, min) Yes
Amylase (SPECIAL/TIME, min) Yes
Ast (BASIC/TIME, min) Yes
Bun (BASIC/TIME, min) Yes
Ca++ (TESTING RANGE, MMOL/L) Yes
Cholesterol (BASIC/TIME, min) Yes
Ck (BASIC/TIME, min) Yes
Cl- (BASIC/TIME, min) Yes
Co2 (BASIC/TIME, min) Yes
Creatinine (BASIC/TIME, min) Yes
Direct and total bilirubin (BASIC/TIME, min) Yes
Glucose (ASSAYS) Yes
Inorgan phosphorus (BASIC/TIME, min) Yes
Iron (BASIC/TIME, min) Yes
Ldh (BASIC/TIME, min) Yes
Mg (BASIC/TIME, min) Yes
Total protein (BASIC/TIME, min) Yes
Triglycerides (BASIC/TIME, min) Yes
Urea (BASIC/TIME, min) Yes
Uric acid (BASIC/TIME, min) Yes
SPECIAL CHEMISTRIES
Acid phosphatase (SPECIAL/TIME, min) Yes
Amylase (SPECIAL/TIME, min) Yes
Ggt (SPECIAL/TIME, min) Yes
Hdl cholesterol (SPECIAL/TIME, min) Yes
Additional (Alarms, high/low) Apolipoprotein A-1 and B, HBDH (available outside USA), Mg; Microgenics applications for thyroid tests
REAGENT DELIVERY (SPECIAL/TIME, min) Automatic
CALIBRATION FREQ (SAMPLE REQUIREMENTS) Test dependent
DIRECT SAMPLING (DRUG ASSAY/TIME, min) Yes
OPTICAL SYSTEM (SPECIAL/TIME, min) See commentsPhotometric, bi/polychromatic (diode array)
SAMPLE REQUIREMENTS
Serum and plasma (SAMPLE REQUIREMENTS) Yes
Urine (TESTING RANGE, MMOL/L) Yes
ABNORMAL VALUES FLAG Yes
AUTO CALIBRATION (WATER REQUIREMENTS, L/min) Yes
REAGENT USED Liquid
RESULTS PER HOUR (SPECIAL/TIME, min) 180; 340 with ISE
POWER LOSS RECALIBRATION (PURCHASE INFORMATION) Calibration, patient
AUTO QUALITY CONTROL (SPECIAL/TIME, min) Yes
ILLUMINATION SOURCE Tungsten-halogen
TEST METHODS (SAMPLE REQUIREMENTS) End point, kinetic, rate
DISPLAY CRT, resident 40-column printer
REAGENT SUBSTITUTION (SPECIAL/TIME, min) Yes
MAX. CAPACITY SAMPLE TRAY (SPECIAL/TIME, min) 40 cups or 20 tubes
REAGENT PREPARATION Yes
MAINTENANCE (WAVELENGTH, nm) 1/year
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY) 56x 102 x 58 (22x 40 x 23)
WEIGHT, kg (lb) (DISPLAY) 77 (170)
PRE-PROGRAMMED TESTS (SPECIAL/TIME, min) 29
OTHER ATTRIBUTES (Interference compensation) Primary tube sampling; 26-position reagent tray
MARKETING REGION (Interference compensation) Worldwide
Disclaimer
Information on this page may be partial or incomplete and may contain mistakes or inaccurate information.
MedWOW disclaims any obligation, responsibility or liability which concerns or relates to any information on this page.
Highlights
♦ Original Instrumentation provided by Thermo Fisher Scientific.
♦ Total number of assays tested: 64.
♦ Diamond Down-To-Frame® refurbishment provided.
♦ Refurbishment includes disassembly and total restoration.
♦ Process continues with assembly, repair, and diagnostics.
♦ Certification concludes with calibration, QC and QA validation.
♦ Contact Diamond for pricing, specifications and availability.
Assays
Total assays tested: 64 – Acid Phosphatase (ACP), Alanine Aminotransferase (ALT)…
DCA 2000+
Manufactures: Bayer/Siemens
System Description: Analyzer for the measurement of glycated haemoglobin (HbA(1c)
Purpose of use: With this device, you can calculate low concentrations of albumin, creatinine and albumin/creatinine ratio in urine.
Time to Test Results: HbA1c – 6 minutes, A:C Ratio – 7 minutes
This analyzer is useful to make immediate diabetes management adjustments, and thus protect the patients from the risks of retinopathy, neuropathy, and nephropathy.

Provide the clinical confidence your patients deserve. The DCA Vantage® Analyzer helps you monitor glycemic control and detect early kidney disease in environments ranging from the physician’s office to remote, point-of-care coordinated sites in hospitals and multisite practices. Meet lab-quality testing standards with an analyzer that speeds and simplifies diabetes tests and delivers accurate,1 clinically relevant results shown to improve decision-making,2,3 patient compliance, and outcomes.4
Manage diabetes patients more effectively
Improve workflow in office or clinic
Simplify management of diabetes testing in decentralized settings
One of just two HbA1c analyzers that meet NGSP performance criteria1
Used by three out of four physicians who perform HbA1c testing in their office5
The Beckman Unicel DxC 600 supported by Beckman Coulter Inc. is routinely available from Diamond Diagnostics in refurbished condition. All instruments refurbished by Diamond, including the Beckman Unicel DxC 600, are disassembled down to-the-frame then thoroughly cleaned, polished and eventually refinished with a durable 3 part industrial paint that matches the instrument’s original color and sheen. During re-assembly components are validated, repaired or replaced as needed followed by full diagnostics, calibration and running controls as a final step. Afterward the instruments are inspected and prepared for international transit. Should you wish to receive more information on the Beckman Unicel DxC 600 Chemistry Analyzer such as pricing, detailed specifications and availability go to Analyzer Search.
Beckman Unicel DxC 600
Manufacturer: Beckman Coulter Inc.
Type Chemistry Analyzer
Parameters: 96 analytes
Throughput: 990 samples/hour
Method: Spectrophotometric
Open system: Open
W x D x H: 61X41X62 inches / 158X104X158 cm
Weight: 1570 lbs / 714 kilos

The perfect solution for laboratories with a throughput of 25,000 to 250,000 tests per year or 50 to 250 samples per day
Broad test menu comprising over 120 assays and applications that consolidate clinical chemistry with specific proteins, therapeutic drug monitoring and drug of abuse testing
Compact tabletop analyzer offering maximum versatility to improve efficiency and reduce costs
Uses convenient cobas c pack reagent format which standardizes patient results across integrated laboratory networks
- wielofunkcyjny analizator biochemiczny o dowolnym dostępie przeznaczony dla małych i średnich laboratoriów, benchtop
- wydajność do 340 testów fotometrycznych/godz, do 400 testów/ godz. z ISE
- system odczynnikowy zamknięty
- ponad 150 różnych aplikacji dla panelu z zakresu : enzymów, substratów, białek specyficznych, leków, substancji uzależniających, elektrolitów i koagulologii
The cobas 6000 analyzer series offers new dimensions in increased efficiency, quality of results, maximum uptime and optimized workflow:
Intelligent sample workflow
Up to 340 immunoassay tests per hour and up to 2,000 clinical chemistry tests per hour depending on configurations
Combines STAT and routine testing without disruption
Unique reagent concept
No preparation or mixing required
Economic usage with high stabilities and convenient kit sizes
First class performance
State-of-the-art immunoassay testing using ElectroChemiLuminescence (ECL) technology
Sample and result integrity deliver high quality results (e.g. test-specific serum indices, disposable immunoassay tips and cups, and clot detection)
Professional management of lab processes:
Wide range of complete pre and post-analytical solutions from small Task Target Automated to Total Lab Automation

The cobas c501 analyzer is a mild-volume clinical chemistry analyzer, which has flexible combination of clinical chemistry. The analyzer is used for produce clinical chemistry tests in laboratories.
Features:
Clinical chemistry, ISE (K,Na, CI), over 100 Homogeneous Immunoassays, HbA1c
Up to 1000 tests per hour throughput
60 direct-access assays
Automatic reagent loading during operation
Specimen integrity via serum indices, clot and liquid level detection
Contact-free ultrasonic mixing
Automated rerun and dilution

The smallest member of cobas serum work area platform family
Ideal compact solution for clinical chemistry testing in laboratories running up to 50 samples per day or a throughput up to 25,000 tests per year
Comprehensive test menu and easy integration of STAT samples
Supports testing of both routine clinical chemistry panels and rapid turnaround critical care markers
Uses the same reagent formulations as the larger cobas clinical chemistry analyzers
Standardizes patient results, which is vital for integrated laboratory networks serving outpatient services, emergency departments and clinics, as well as private laboratories serving primary care physicians

The Roche Cobas E411 supported by Roche Diagnostics is routinely available from Diamond Diagnostics in refurbished condition. All instruments refurbished by Diamond, including the Roche Cobas E411, are disassembled down to-the-frame then thoroughly cleaned, polished and eventually refinished with a durable 3 part industrial paint that matches the instrument’s original color and sheen. During re-assembly components are validated, repaired or replaced as needed followed by full diagnostics, calibration and running controls as a final step. Afterward the instruments are inspected and prepared for international transit.
Manufacturer: Roche Diagnostics
Type Immunology Analyzer
Parameters: 18 assays
Throughput: 88 samples/hour
Method: CLIA
Open system: Closed
W x D x H: 47X28X22 inches / 119X72X55 cm
Weight: 374 lbs / 170 kilos

Roche Cobas Mira Plus CC is a flexible and convenient chemistry analyzer developed by Roche Diagnostics Systems. It can perform special chemistries, tests for drugs of abuse, electrolytes, TDM’s, and routine profiles in an effective and accurate manner.
Laboratory Information System (LIS) options allow you to receive the test results in the format of your choice. The analyzer can conduct 132 tests per hour and with an ISE module up to 204 tests per hour.
Features
Random-access testing flexibility
Extensive list of test menu including STAT capability
Reagent capacity up to 33 reagents.
Dade Behring Dimension RXL Chemistry Analyzer
Specification
Manufactures: Dade Behring
Method: Filter photometric
Parameters: 79 analytes
Throughput: 740 samples/hour
Sample volume: from 40-60 uL
The Dade Behring Dimension RXL chemistry analyzer ensures productivity by enhancing the efficiency of laboratory procedures.

80 method options
Consistent dimension platforms for synergy across testing sites
Simple load-and-go operation
Single station, multi-tasking workstation connectivityThe Dade Dimension® Xpand® integrated chemistry system offers versatility in a compact frame for smaller laboratories.


MODEL
Lisa 400
OPTICAL SYSTEM (SPECIAL/TIME, min) See commentsColorimetric, ISE
POWER USAGE 500VA
PRE-PROGRAMMED TESTS (SPECIAL/TIME, min) 96
REAGENT DELIVERY (SPECIAL/TIME, min) Automatic
YIELD, 20 TEST PROFILES/HR 13.3
AUTO DILUTION (PURCHASE INFORMATION) Yes
RESULTS PER HOUR (SPECIAL/TIME, min) 480
AUTO CALIBRATION (WATER REQUIREMENTS, L/min) Yes
Analizator chemiczny Olympus AU 600
S/N: 707520
Parametry badane: 99
Wydajność pracy: 800 próbek/h, lub 1200 próbek/h (ISE)
Metoda: spektrofotometryczna
Wymiary (cm): 168x80x120 + wózek 70x70x143
Waga (kg): 480+ wózek 70kg
OLYMPUS AU600 jest w pełni automatycznym chemicznym analizatorem o dostępie bezpośrednim mającym zastosowanie w laboratoriach, gdzie szczególnie ważna jest duża wszechstronność próbek, wysoka jakość wyników oraz przekonywująca ekonomia pracy.
Został rozbudowany dla średnich i dużych wydajności próbek; imponuje lekkością obsługiwania. Aparat jest zdolny do przetworzenia 800 fotometrycznych testów na godzinę. Włączając auto podtrzymywanie jednostki ISE aż do 1200 testów na godzinę.
Przystosowany jest do szerokiego spektrum rutynowych i specyficznych chemikaliów (51 analiz na pulpicie i aż do 98 dostępnych parametrów); umożliwia badanie szerokiego zakresu analitycznych potrzeb włączając DAT, TDM, hormony i specyficzne białka.
Zawiera STAT rotor z 18 pozycjami. Przetwarzanie próbki może następować albo przez podstawowe probówki albo przez specjalne kubki STAT. Specjalna aplikacja STAT może być uruchomiona w każdej chwili. Przygotowane stabilne ciekłe reagenty są dostarczane w losowo wydzielonych fiolkach i odcinkowe ułożone w komorze reagentów. Elastycznie oprogramowanie pozwala używać specyficznej i indywidualnej konfiguracji. Klawisze funkcyjne i mysz, tablica menu i wyczerpujący poradnik umożliwiają szybko zaznajomić się z systemem pracy i uproszczają operowanie aparatem.
Olympus OLA2500™ laboratory automation solution is a high performance system designed for use within medium- to high-volume clinical labs and sample processing departments. It features advanced aliquotting, along with pre- and post-analytical sample processing capabilities. As a front-end sample processor, the system automatically decaps, aliquots and sorts tubes to any analyzer sample rack. This saves time and labor, and eliminates sample handling errors. The Olympus OLA2500 laboratory automation system also uses an on-board digital imaging system to check sample volume as well as identify tube size, cap type and color.
As a modular system, the Olympus OLA2500 laboratory automation system can be configured for expanded capability to keep pace with individual lab needs and growth. In a standard configuration, the system typically processes as many as 650 tubes per hour, making it ideal for peak workload periods in medium and high volume labs. The system handles a wide variety of tube sizes, along with screw caps, rubber stoppers and aluminum seals.
The system uses a Windows® 2000 operating system, Pentium® processor, graphic user interface and image recognition software. It also comes with a high-reliability touch screen and membrane switches for easy use.
The Pointe 180 is a small, semi-automated chemistry analyzer with six filters and a large test menu. It has an onboard incubator with 12 wells at 37° C, a temperature controlled cuvette well, and internal temperature control. The analyzer leads the user through test performance in a step-by-step manner. The new graphics software allows extended timed absorbance interval data and kinetic data plots to be printed.
The analyzer has 48 programmed and 21 open channels, and reads, calculates, and prints results in less than three seconds. The analyzer reads test tubes upon insertion—-no need to press a button. Optimized parameters for Pointe Scientific reagents are already entered – just select the test number. Open channels are available for programming other tests. The normal range for each test is automatically printed out, and results that are out of the normal range are flagged. Normal ranges can be edited to fit the area or population. Results generated by the Pointe 180 are comparable to results reported by hospital and reference labs.
The analyzer can use single point calibration by standard/factor, multi-point calibration with point to point curve fit, percent absorbance and rate by standard or factor. These calculation options allow the analyzer to perform endpoint, initial rate, kinetic rate and batch kinetic methodologies.
-
filtry – zakres dł. fal 340-900nm (można zainstalowac 12 dł. fal)
-
Źródło światła – lampa halogenowa
-
kuwety – standardowe makro i półmikro
-
błąd pomiaru – 1% lub 0,003A w całym zakresie
-
termostatowe gniazdo pomiarowe – 25 oC, 30 oC, 37 oC
-
zasilanie – 220V
-
Wymiary – 480 x 153 x 330 mm
-
ciężar – 9,75 kg
-
wbudowana drukarka termiczna
-
ilość programów pomiarowych – 100

Zintegrowane oprogramowanie umożliwia np. ocenę ryzyka wystąpienia zawału serca. Ilościowe oznaczanie 17 podstawowych parametrów klinicznych:
- cholesterol
- HDL cholesterol
- triglicerydy
- glukoza
- GGT
- GOT
- GPT
- kreatynina
- mocznik
- kwas moczowy
- alfa-amylaza
- amylaza trzustkowa
- CPK
- hemoglobina
- potas
- fosfataza alkaliczna
- bilirubina

Hitachi 904 to w pełni zautomatyzowany analizator składający się z dwóch jednostek: jednostki sterującej oraz jednostki analitycznej.
Jest to kompletny system z czujnikami, podręczniki i wylotodpadów. Jest w stanie wykonać zarówno potencjometryczne i fotometryczne testy. Do testów fotometrycznych, ma przepustowość 180 testów na godzinę. Jego moduł ISE, o przepustowości 380 testów na godzinę, pozwala na automatyczną kalibrację sodu, potasu i chlorku
The Roche Hitachi 911 Chemistry Analyzer is a fully automated and computerized system, composed of two parts: the analytical and the control units. The analytical component of this Roche chemistry analyzer operates with the photometric measuring technology called the Ion-Selective Electrodes (ISE) system and a CPU. The control unit consist of a monitor (CRT), keyboard, and a printer. Other highlights of the Hitachi 911 include automatic calibration, quick delivery of STAT results and 24-hour use per day.
The Hitachi 911 chemistry analyzer makes use of various sample types including serum, urine, plasma and Cerebral Spinal Fluid (CSF) to perform in vitro quantitative and qualitative tests on a wide range of analytes. Potentiometric and photometric assays are also performed by this model.
Hitachi 911 supports the following assay types:
Monochromatic
Bi-chromatic
Endpoint
Kinetic
Simultaneous endpoint and kinetic
Endpoint with sample blanking
Kinetic with sample blanking
Simultaneous double endpoint and double kinetic
The BN™ II System and its nephelometric technology provide uncompromising performance in plasma protein analysis. The menu covers assays to support a variety of clinical indications, such as cardiac risk assessment, kidney diseases, nutritional assessment, and innovative markers such as monoclonal kappa and lambda free light chains, Cystatin C and Carbohydrate-Deficient Transferrin (CDT).
Ideal for mid- to high-volume plasma protein throughput
Comprehensive menu from one source: Over 64 assay protocols available for determination of various sample types
Up to 100 samples onboard
Antigen-excess security for confidence in results
Assistance with clinical interpretation through our innovative range of assessment programs available for Protis® Data Management System*
The BN ProSpec® is a dedicated, compact system that offers a consolidated menu of specialty and routine reagents for reliable plasma protein testing including cardiac risk assessment, kidney diseases, nutritional assessment and iron and anemia assessment as well as innovative markers such as monoclonal kappa and lambda free light chains, Cystatin C and Carbohydrate-Deficient Transferrin (CDT).
Ideal for low- to mid-volume plasma protein throughput
Comprehensive menu from one source: Over 64 assay protocols available for determination of various sample types
Optimal alignment of systems and reagents
Refrigerated onboard storage of controls and reagents
Assistance with clinical interpretation through our innovative range of assessment programs available for Protis® Data Management System.
Zakres długości falowej: 340 – 850 nm
Szerokość spektralna: 11 nm
Dokładność długości falowej: 1 nm
Powtarzalność długości falowej: < 0.2 nm
Zakres pomiaru absorpcji: -2 do 2 ABS
Odczyt wartości pomiarowych: cyfrowy
Możliwość pomiarów transmitancji, absorbancji, koncentracji oraz pomiarów kinetycznych. Możliwość podłączenia drukarki.
StreamLAB® Automation Solutions let you streamline your workflow by automating manual steps with highly flexible, compact configurations for efficient space utilization and minimal lab disruption during implementation.
Accelerate diagnosis – Deliver timely and consistent lab services
Gain process efficiency – Eliminate unnecessary steps including pre-analytical sorting and aliquotting
Provide an expansive menu – Consolidate routine and stat workload
Enjoy an optimal footprint – Optimize space utilitization; minimize disruption during installation
Be Confident – Achieve built-in redundancy processing and automatic workload rebalancing with fully integrated IT solutions
Automatyczny przebieg etapów elektroforezy: rozdział, inkubacja, barwienie, wybarwianie i suszenie
Możliwość wykonania rozdziałów: białko surowicy, immunofiksacja (IF, IF Bence Jones, IF Penta, PMR), lipoproteiny + Lp(a), LDL/HDL CHOL Direct, HbA1c, Hb, Izoenzymy (LDH, ALP, CK)
Automatyczna aplikacja próbki na żel
Możliwość prowadzenia 7, 15, 30 lub 54 rozdziałów elektroforetycznych na jednej płytce
Aplikacja 10 μl materiału biologicznego na 1 ścieżkę rozdziału
Zastosowanie aplikatorów jednorazowego użytku do nanoszenia materiału biologicznego na żel
Jednoczesna obróbka 54 próbek białka, 9 IF lub 15 próbek hemoglobiny
Wydajność:
* Białko: 162 próbki na godzinę
* Immunofiksacja: 18 próbek na godzinę
Automatyczna regulacja napięcia, prądu i mocy
Kontrola temperatury poprzez system Peltier podłączony do wymiennika ciepła
Proces utrwalania rozdziałów elektroforetycznych z wykorzystaniem metody termicznej
Programowanie i dialog za pomocą klawiatury i ekranu: możliwość zaprogramowania 50 rozdziałów
Komora do barwienia z możliwością wykorzystania 6 różnych odczynników
Samokontrola – program testowy – sygnalizacja błędów
Akcesoria do immunofiksacji (opcja)
Akcesoria do lipo/enzymów (opcja)

The VITROS® 350 Chemistry System offers easy operation, maintenance, and training. Whether you use it as a primary, STAT, or backup to the powerful VITROS® 5,1 FS, the VITROS® 350 Chemistry System will get the job done right the first time.
You know that VITROS® Systems are efficient, dependable, and easy-to-use. The VITROS® 350 comes complete with enhanced throughput, a broad accessible menu, and new ergonomic design. Boost your productivity and reduce costs with the system that delivers the right results the first time.
The VITROS®; 350 Chemistry System delivers low cost per reportable result and high reagent efficiency without the costs, maintenance, preparation, carryover, and interference associated with traditional water-based and indirect ISE systems.
Up to 300 results per hour with on-board capacity for all 45 assays
Primary tube sampling
On-board dilution
Optional positive patient identification via barcode scanner
Flexible processing for manual, stat, or automated testing
The VersaCell™ System transforms chemistry and/or immunossay sample management for simple, versatile workflow consolidation.
Single, consilidated workstation for effective management of peak workloads with reduced staff.
Simple to operate, with a single input area for a consolidated solution.
Flexible solution preserving functional independence of workstations if desired.
200 samples/hour; continuous feed; no aliquotting required.
Simple to Operate, Easy to Consolidate
The VersaCell™ system redefines simplicity. You simply open the sample drawer, load sample tubes, and close the drawer – the VersaCell™ system does the rest:
Easy-access drawers for continuous sample loading and unloading with no interruption to test processing streamlines workflow
The VersaCell™ system orients the sample tubes for barcode reading – you don’t have to
STAT samples are loaded as easily as routine and automatically prioritized
Operate instruments as if stand-alone—no additional skills needed
Simple design means no tracks and small footprint for easy integration into your existing floor plan
The V-Twin® System maximizes the performance of your gold standard Syva® EMIT® reagents. Fast and easy to use, it processes more tests at lower cost, incorporating its own backup system for greater reliability. A broad range of assays for drugs of abuse, therapeutic drugs and immunosuppressants makes drug testing more convenient than ever.
Twin-unit design, incorporating its own backup system
Built on years of experience with the Viva system
Up to 26 EMIT reagents simultaneously onboard
Long walkaway time to keep hands free for other important work
State-of-the-art software in combination with ease of operation
Broad menu of drugs of abuse, validity testing, toxicology, and therapeutic drug testing assays including immunosuppressive drug testing assays
The Viva-E® System provides a complete menu of gold standard EMIT® assays for fast analysis of drugs of abuse, therapeutic drugs and immunosuppressants, as well as sample validity testing on a single bench top analyzer. This easy-to-use system is designed to meet all your drug testing needs. Easy to use: user-friendly interface based on Windows® software
Efficient: liquid ready-to-use reagents stored on board; minimal calibration/control requirements; very little maintenance required
Effective: results ready in as little as 10 minutes
Excellence: features Syva® EMIT® Assays – the gold standard in drugs of abuse testing
Enduring expertise: 40 years of experience creating a solid groundwork to support your daily work
Extensive menu for drugs of abuse, validity, toxicology and therapeutic drug testing including immunosuppressive drug testing